Filtration, regulation and treatment of compressed air, Page 17
-
Treatment units; basic units for air
-
Industrial filtration; ISO 8573 - ISO 12500
-
Air dryers; air moisture removal
-
Pressure regulators; precision robust design
-
Cyclone separators; cyclone filtration principle
-
Water-oil separators; separates water from oil
Bestsellers

AAFA 3" activated carbon filter for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1. Body with easily...

Absorption filter with activated carbon 0,005 um, 1/2" connection, for compressed air and neutral gases with flow rate 1 250 l/min. Design according to ATEX II 2G2D. Maximum...

Absorption filter with 0.005 um activated carbon, 3/4" connection, for compressed air and neutral gases with a flow rate of 3,500 l/min. Design according to ATEX II 2G2D....

Absorption filter with 0.005 um activated carbon, 3/8" connection, for compressed air and neutral gases with a flow rate of 1,250 l/min. Design according to ATEX II 2G2D....

Filter with AAFMS2 molecular sieve capsule in 1" version designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...

Filter with AAFMS2 molecular sieve capsule in 1" version designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...

Capsule filter with AAFMS2 molecular sieve in 1/2" version designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...

Capsule filter with AAFMS2 molecular sieve in 3/4" design designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...

Basic 5 um air filter with 1" connection for compressed air and neutral gases with a flow rate of 8,000 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 - 16...

Basic 5 um air filter with 1/4" connection for compressed air and for neutral gases with a flow rate of 2,200 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5...

Basic 5 um air filter with 3/4" connection for compressed air and neutral gases with a flow rate of 8,000 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 -...

Basic 5 um air filter with 3/8" connection for compressed air and neutral gases with a flow rate of 2,200 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 -...

Basic 5 um air filter with 3/8" connection for compressed air and neutral gases with a flow rate of 3,500 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 -...

Modular filter system PPA-207 for supplying clean air with a pre-supervised air dryer in ducts. Concept combining pre-filter, microfilter, pressure regulator and 2 quick...

Modular filtration system PPA-207C for clean air supply without air dryer in the ducts. Concept combining microfilter, cyclone separation, dryer, pressure regulator and quick...

PPA-307 modular filtration system for clean air supply with pre-set air dryer in ductwork. Concept combining microfilter, activated carbon, pressure regulator and 2 quick...

Modular filtration system PPA-307C for clean air supply without air dryer in the ducts. Concept combining cyclone separator, pre-filter, microfilter, pressure regulator and 2...

The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN80 clearance....

The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN100 clearance. The...

The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN125 clearance....

The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN150 clearance....

The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN80 clearance....

The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN100 clearance. The...

The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN125 clearance....

The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN150 clearance....

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN80...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN100...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN125...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN150...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN80...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN100...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN125...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN150...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN80...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN100...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN125...

The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN150...

The filters are used to remove mechanical impurities from compressed air up to 3 um according to ISO 8573-1 class 6. Connection by flange with DN80 clearance. Designed for flow...

The filters are used to remove mechanical impurities from compressed air up to 3 um according to ISO 8573-1 class 6. Connection by flange with DN100 clearance. The design allows...

The filters are used to remove mechanical impurities from compressed air up to 3 um according to ISO 8573-1 class 6. Connection by flange with DN125 clearance. Designed to allow...