Průmyslové vzduchové filtry bez odpouštěče kondenzátu, Page 15
- Omega air filters; pressure 16 to 64 bar
- High pressure filters; 100 - 400 bar
- NGF air filtration; including clogging indication
- Stainless steel process filters; air and gas distribution
- Sterile stainless steel filters; SFS and SPF filtration
- Vacuum filters; filtration for vacuum
- PPA filter system; for painting equipment
- B-AIR filtration; for breathable air
- Filters in AFS design; silicone-free filtration
- Accessories for filters; inserts, indications,...
PFN5 screen filter with DN150 flange connection for use in areas with high corrosive environments. Filtration capacity up to 5 um. Maximum working pressure is 10 bar, maximum...
PFN5 screen filter with DN200 flange connection for use in areas with high corrosive environments. Filtration capacity up to 5 um. Maximum working pressure is 10 bar, maximum...
PFN5 screen filter with DN200 flange connection for use in areas with high corrosive environments. Filtration capacity up to 5 um. Maximum working pressure is 10 bar, maximum...
Designed for cleaning compressed air of coarse mechanical impurities up to 3 um according to ISO 8573-1 class 6. Connection by internal pipe threads 1/2". The design allows flow...
Designed to clean compressed air from mechanical impurities and oil up to 0.1 um according to ISO 8573-1 class 2. Connection by internal pipe threads 1/2". The design allows...
Removes microscopic mechanical impurities and oil from compressed air up to 0.01 um according to ISO 8573-1 class 1. Connection by internal pipe threads 1/2". The design allows...
Removes microscopic mechanical impurities and oil from compressed air up to 0.01 um according to ISO 8573-1 class 1. Connection with 3/4" internal pipe threads. The design...
Removes microscopic mechanical impurities and oil from compressed air up to 0.01 um according to ISO 8573-1 class 1. Connection with internal pipe threads 3/8". The design...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN80...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN100...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN125...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN150...
Microfilter IHP1S with G1 1/2" connection thread for effective removal of solid impurities, oil, odour and other impurities from compressed air up to 0.01 um. Maximum working...
The IHP1S microfilter with G1/4" connection thread effectively removes solid impurities, oil, odour and other impurities from compressed air up to 0.01 um. Maximum working...
Microfilter IHP1S with G2 connection thread" for effective removal of solid impurities, oil, odour and other impurities from compressed air up to 0.01 um. Maximum working...
CHP1R pre-filter with G1" connection thread for effective removal of solid impurities, oil, water and other impurities from compressed air up to 1 um. Maximum working pressure...
CHP1R pre-filter with G2" connection thread for effective removal of solid impurities, oil, water and other impurities from compressed air up to 1 um. Maximum working pressure...
CHP2R pre-filter with G1" connection thread for effective removal of solid impurities, oil, water and other impurities from compressed air up to 1 um. Maximum working pressure...
CHP4R pre-filter with G1" connection thread designed for effective removal of solid impurities, oil, water and other impurities from compressed air up to 1 um. Maximum working...
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN80 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN100 clearance. The...
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN125 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN150 clearance....
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN80 clearance....
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN100 clearance. The...
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN125 clearance....
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN150 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN80...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN100...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN125...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN150...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN80...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN100...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN125...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.1 um and oil according to ISO 8573-1 class 2. Connection by flange with DN150...
The filters are used to remove mechanical impurities from compressed air up to 3 um according to ISO 8573-1 class 6. Connection by flange with DN80 clearance. Designed for flow...
The filters are used to remove mechanical impurities from compressed air up to 3 um according to ISO 8573-1 class 6. Connection by flange with DN100 clearance. The design allows...
The filters are used to remove mechanical impurities from compressed air up to 3 um according to ISO 8573-1 class 6. Connection by flange with DN125 clearance. Designed to allow...
The filters are used to remove mechanical impurities from compressed air up to 3 um according to ISO 8573-1 class 6. Connection by flange with DN150 clearance. Designed for flow...
Activated carbon filter CHP2A with G1 1/2" connection thread designed to effectively remove solid impurities, oil, water and other impurities from compressed air up to 0.01 um....