Filtration, regulation and treatment of compressed air, Page 40
- Treatment units; basic units for air
- Industrial filtration; ISO 8573 - ISO 12500
- Air dryers; air moisture removal
- Pressure regulators; precision robust design
- Cyclone separators; cyclone filtration principle
- Water-oil separators; separates water from oil
Bestsellers
The SFS filter with DN10 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN100 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01...
The SFS filter with DN100 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01...
The SFS filter with DN15 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN15 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN25 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN32 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN40 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN50 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN65 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
The SFS filter with DN80 flange connection is designed for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
Absorption filter with activated carbon 0,005 um, 1/2" connection, for compressed air and neutral gases with flow rate 1 250 l/min. Design according to ATEX II 2G2D. Maximum...
Absorption filter with 0.005 um activated carbon, 3/4" connection, for compressed air and neutral gases with a flow rate of 3,500 l/min. Design according to ATEX II 2G2D....
Absorption filter with 0.005 um activated carbon, 3/8" connection, for compressed air and neutral gases with a flow rate of 1,250 l/min. Design according to ATEX II 2G2D....
Filter with AAFMS2 molecular sieve capsule in 1" version designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...
Filter with AAFMS2 molecular sieve capsule in 1" version designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...
HFPA sterile cartridge filter with G1" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50...
HFPA sterile cartridge filter with G1 1/2" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up...
HFPA sterile cartridge filter with G1 1/4" connection thread for use in high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50 bar,...
Filter with sterile HFPA liner with G1/2" connection thread for use in high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50 bar,...
Filter with sterile HFPA liner with G2" connection thread for use in high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50 bar,...
HFPA sterile cartridge filter with G3" connection thread for use in high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to 50 bar,...
HFPA sterile cartridge filter with G3/4" connection thread for use in areas with high corrosive environments. Filtration capacity up to 0.01 um. Maximum working pressure up to...
Basic 5 um air filter with 1" connection for compressed air and neutral gases with a flow rate of 8,000 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 - 16...
Basic 5 um air filter with 3/8" connection for compressed air and neutral gases with a flow rate of 2,200 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 -...
Basic 5 um air filter with 3/8" connection for compressed air and neutral gases with a flow rate of 3,500 l/min. Design according to ATEX II 2G2D. Maximum inlet pressure 1,5 -...
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN80 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN100 clearance. The...
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN125 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 1 um according to ISO 8573-1 class 3. Connection by flange with DN150 clearance....
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN80 clearance....
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN100 clearance. The...
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN125 clearance....
The filters are used to remove the largest mechanical impurities from compressed air up to 15 um according to ISO 8573-1 class 7. Connection by flange with DN150 clearance....
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN80...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN100...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN125...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN150...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN80...
The filters are used to remove the smallest mechanical impurities from compressed air up to 0.01 um and oil according to ISO 8573-1 class 1. Connection by flange with DN100...