With a ø 17.2 mm pipe connection and a flow of 1,250 l/min at 7 bar, the WFIWN5-005 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar, welded...
With a ø 21.3 mm pipe connection and a flow of 2,500 l/min at 7 bar, the WFIWN5-010 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar, welded...
With a ø 26.9 mm pipe connection and a flow of 3,750 l/min at 7 bar, the WFIWN5-018 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar, welded...
With a ø 33.7 mm pipe connection and a flow of 5,250 l/min at 7 bar, the WFIWN5-030 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar, welded...
With a ø 42.4 mm pipe connection and a flow of 7,000 l/min at 7 bar, the WFIWN5-047 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar, welded...
With a ø 48.3 mm pipe connection and a flow of 10,000 l/min at 7 bar, the WFIWN5-070 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar,...
With a ø 60.3 mm pipe connection and a flow of 15,000 l/min at 7 bar, the WFIWN5-094 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar,...
With a ø 60.3 mm pipe connection and a flow of 21,000 l/min at 7 bar, the WFIWN5-150 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar,...
With a ø 76.1 mm pipe connection and a flow of 28,000 l/min at 7 bar, the WFIWN5-175 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar,...
With a ø 88.9 mm pipe connection and a flow of 40,000 l/min at 7 bar, the WFIWN5-200 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar,...
With a ø 88.9 mm pipe connection and a flow of 60,000 l/min at 7 bar, the WFIWN5-240 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 14 bar,...
With a G 1/2" connection and a flow of 2,500 l/min at 7 bar, the WHFITN5-010 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
With a G 3/4" connection and a flow of 3,750 l/min at 7 bar, the WHFITN5-018 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
With a G 1" connection and a flow of 5,250 l/min at 7 bar, the WHFITN5-030 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
With a G 1 1/4" connection and a flow of 7,000 l/min at 7 bar, the WHFITN5-047 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
With a G 1 1/2" connection and a flow of 10,000 l/min at 7 bar, the WHFITN5-070 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
With a G 2" connection and a flow of 15,000 l/min at 7 bar, the WHFITN5-094 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
With a G 2" connection and a flow of 21,000 l/min at 7 bar, the WHFITN5-150 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
With a G 3" connection and a flow of 40,000 l/min at 7 bar, the WHFITN5-200 basic filter traps solid contaminants larger than 5 µm. Working pressure up to 50 bar, welded...
Kit for the N1 bowl of M-VAC medical vacuum filters.
Kit for the N2 bowl of M-VAC medical vacuum filters.
Kit for the N3 bowl of M-VAC medical vacuum filters.
The transparent bowl collects the liquid from the M-VAC filter; it can be removed and sterilised.
The transparent bowl collects the liquid from the M-VAC filter; it can be removed and sterilised.
The transparent bowl collects the liquid from the M-VAC filter; it can be removed and sterilised.
Three-stage Omega Air B-AIR set for preparing compressed breathing air: S microfilter 0.01 µm, H2 catalytic filter and A2 adsorption filter with activated carbon. G 1/2", 1,300...
Three-stage Omega Air B-AIR set for preparing compressed breathing air: S microfilter 0.01 µm, H2 catalytic filter and A2 adsorption filter with activated carbon. G 3/4", 2,000...
Three-stage Omega Air B-AIR set for preparing compressed breathing air: S microfilter 0.01 µm, H2 catalytic filter and A2 adsorption filter with activated carbon. G 1", 3,300...
Three-stage Omega Air B-AIR set for preparing compressed breathing air: S microfilter 0.01 µm, H2 catalytic filter and A2 adsorption filter with activated carbon. G 1", 5,583...
Three-stage Omega Air B-AIR set for preparing compressed breathing air: S microfilter 0.01 µm, H2 catalytic filter and A2 adsorption filter with activated carbon. G 1 1/2",...
Three-stage Omega Air B-AIR set for preparing compressed breathing air: S microfilter 0.01 µm, H2 catalytic filter and A2 adsorption filter with activated carbon. G 1 1/2",...
With a G 3/4" thread and a flow of 2,000 l/min at 7 bar, the AAFH2-120 catalytic filter reduces carbon monoxide CO and some other substances in breathing air, but not carbon...
With a G 1" thread and a flow of 3,300 l/min at 7 bar, the AAFH2-198 catalytic filter reduces carbon monoxide CO and some other substances in breathing air, but not carbon...
With a G 1 1/2" thread and a flow of 8,500 l/min at 7 bar, the AAFH2-510 catalytic filter reduces carbon monoxide CO and some other substances in breathing air, but not carbon...
With a G 1/2" thread and a flow of 1,300 l/min at 7 bar, the AAFH2-78 catalytic filter reduces carbon monoxide CO and some other substances in breathing air, but not carbon...
With a G 1 1/2" thread and a flow of 13,000 l/min at 7 bar, the AAFH2-780 catalytic filter reduces carbon monoxide CO and some other substances in breathing air, but not carbon...
With a G 2" thread and a flow of 16,667 l/min at 7 bar, the AAFB-1000 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....
With a G 2" thread and a flow of 25,000 l/min at 7 bar, the AAFB-1500 coarse filter traps coarse solid contaminants larger than 15 µm and protects the finer stages after it....