Industrial compressed air filters ISO 8573.1, Page 8
-
Omega air filters; 16 to 64 bar
-
High pressure filters CHP/IHP; carbon and stainless steel up to 400 bar
-
NGF air filtration; including clogging indication
-
Stainless steel process filters; air and gas distribution
-
Sterile stainless steel filters; SFS and SPF filtration
-
Vacuum filters; filtration for vacuum
-
PPA filter system; for painting equipment
-
B-AIR filtration; for breathable air
-
Filters in AFS design; silicone-free filtration
-
Accessories for filters; inserts, indications,...
Product sorting
List of products
The BFP basic filter cartridge is used to remove mechanical impurities from compressed air. Acrylic fibre and cellulose liner with a filtration capacity of up to 3 μm. Working...
The BFA microfiltration insert is used to remove mechanical impurities and oil from compressed air. Borosilicate microfibre and activated carbon liner with filtration capacity...
Replacement catalytic filters (hopcalite) for OMEGA AIR - AAFH2-198. Suitable for removing CO andCO2 to the level of breathable air from compressed air according to ISO 8573-1...
AFSM silicone-free microfilter with G3" connection thread designed for industrial painting applications, eliminates impurities that degrade the paint quality. Filtration...
The HFA filter cartridge removes mechanical impurities and oil from the compressed air. Borosilicate microfibre insert with activated carbon component with filtration capacity...
Filter cartridge for medical vacuum filter MVAC-0006. Applications mainly in medical devices. Working pressure 20 to 2000 mbar, maximum flow up to 60 l/min.
MDM40C - version with voltage-free electrical contact for remote alarm signalling. Magnetic differential pressure gauges for displaying the orientation state of the filter...
Hankison filter cartridge for HF series air filter type F12. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Adsorption filter with activated carbon for compressed air from Hankison NGF series type CF according to ISO. Filter size F08 with 1" female thread connection. The filter is not...
Adsorption filter with activated carbon for compressed air from Hankison NGF series type CF according to ISO. Filter size F04 with 1/2" female thread connection. The filter is...
Hankison filter cartridge for HF series air filter type F13. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Replacement PFA filter cartridge for filter with filtration capacity up to 0,1 um and working pressure 16 bar. Operating temperature up to 150°C. Contains filtering activated...
Replacement filter cartridge PFI1 for filter with filtration capacity up to 1 um and working pressure 16 bar. Operating temperature up to 150°C. Made of stainless steel strainer.
Replacement filter cartridge PFM for filter with filtration capacity up to 0,1 um and working pressure 16 bar. Operating temperature up to 150°C. Made of borosilicate microfibers.
MVAC medical vacuum filter with G1/4" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
MVAC medical vacuum filter with G1/4" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
MVAC medical vacuum filter with G1/4" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
MVAC medical vacuum filter with G1/8" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
MVAC medical vacuum filter with G3/8" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
AAFA activated carbon filter in 1/4" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
Replacement filter cartridge PFI1 for filter with filtration capacity up to 1 um and working pressure 16 bar. Operating temperature up to 150°C. Made of stainless steel strainer.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
Filter cartridge for HFR filter to remove mechanical impurities from compressed air. Acrylic fibre and cellulose liner with a filtration capacity of up to 1 μm. Working pressure...
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 16 bar. Operating temperature up to 150°C.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 12 bar. Operating temperature up to 150°C.
Replacement filter cartridge PFI20 for filter with filtration capacity up to 20 um and working pressure 12 bar. Operating temperature up to 150°C.
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F17 with 3" female thread connection. The filter is equipped with a clogging...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F16 with 3" internal thread connection. The filter is equipped with a clogging...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F11 with 1 1/2" female threads. The filter is equipped with a clogging indicator...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F10 with 1 1/2" female threads. The filter is equipped with a clogging indicator...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F15 with 2 1/2" female threads. The filter is equipped with a clogging indicator...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F14 with 2 1/2" female threads. The filter is equipped with a clogging indicator...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F13 with 2 1/2" female threads. The filter is equipped with a clogging indicator...