Industrial compressed air filters ISO 8573, Page 16
- Omega air filters; pressure 16 to 64 bar
- High pressure filters; 100 - 400 bar
- NGF air filtration; including clogging indication
- Stainless steel process filters; air and gas distribution
- Sterile stainless steel filters; SFS and SPF filtration
- Vacuum filters; filtration for vacuum
- PPA filter system; for painting equipment
- B-AIR filtration; for breathable air
- Filters in AFS design; silicone-free filtration
- Accessories for filters; inserts, indications,...
Bestsellers
Replacement filter cartridge PFIW1 for filters (PF, HPF) with filtration capacity up to 1 um, working pressure up to 50 bar and flow rate up to 5 250 l/min. Operating...
The HFP filter cartridge is used to remove mechanical impurities from compressed air. Acrylic fibre and cellulose liner with a filtration capacity of up to 3 μm. Working...
The HFP filter cartridge is used to remove mechanical impurities from compressed air. Acrylic fibre and cellulose liner with a filtration capacity of up to 3 μm. Working...
The HFB filter cartridge is used to remove the coarsest mechanical impurities from the compressed air. Sintered bronze insert with filtration capacity up to 15 μm. Working...
The HFB filter cartridge is used to remove the coarsest mechanical impurities from the compressed air. Sintered bronze insert with filtration capacity up to 15 μm. Working...
The IHPA-030V filter cartridge is used to remove the largest mechanical impurities from compressed air. Filtration capacity up to 0.01 um. Operating temperature from +1.5 to +65...
The IHPM-030V filter cartridge is used to remove the largest mechanical impurities from compressed air. Filtration capacity up to 0.1 um. Operating temperature from +1.5 to +65 °C.
The IHPM-018V filter cartridge is used to remove the largest mechanical impurities from compressed air. Filtration capacity up to 0.1 um. Operating temperature from +1.5 to +65 °C.
The HFA filter cartridge removes mechanical impurities and oil from the compressed air. Borosilicate microfibre insert with activated carbon component with filtration capacity...
The HFA filter cartridge removes mechanical impurities and oil from the compressed air. Borosilicate microfibre insert with activated carbon component with filtration capacity...
The CHPS filter insert is used to remove mechanical impurities from compressed air. Borosilicate microfibre insert with a filtration capacity of up to 0.01 μm. Operating...
The IHPA-018V filter cartridge is used to remove the largest mechanical impurities from compressed air. Filtration capacity up to 0.01 um. Operating temperature from +1.5 to +65...
Filter cartridge for HFM filter to remove mechanical impurities and oil from compressed air. Borosilicate microfibre insert with a filtration capacity of up to 0.1 μm. Working...
Filter cartridge for medical vacuum filter MVAC-2006V. Applications mainly in medical devices. Working pressure 20 to 2000 mbar, maximum flow up to 4500 l/min.
Replacement filter cartridge PFM for filter with filtration capacity up to 0,1 um and working pressure 16 bar. Operating temperature up to 150°C. Made of borosilicate microfibers.
MVAC medical vacuum filter with G3/4" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
CFS filter cartridge for removing mechanical impurities and oil from compressed air. Borosilicate fibre insert with a filtration capacity of up to 0.01 μm. Working pressure up...
Designed for cleaning compressed air of microscopic mechanical impurities and oil up to 0.01 um according to ISO 8573-1 class 1. Connection with internal pipe threads 3/8". The...
CFS filter cartridge for removing mechanical impurities and oil from compressed air. Borosilicate fibre insert with a filtration capacity of up to 0.01 μm. Working pressure up...
Replacement sintered bronze filter cartridge 15 µm for OMEGA AIR filter AAFB-2160. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge...
Replacement sintered bronze filter cartridge 15 µm for OMEGA AIR filter AAFB-2760. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge...
Capsule filter with AAFMS2 molecular sieve in 3/4" design designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...
Replacement sintered bronze 15 µm filter cartridge for OMEGA AIR AAFB-780 filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the filter cartridge...
Replacement filter cartridge PFIW1 for filters (PF, HPF) with filtration capacity up to 1 um, working pressure up to 50 bar and flow rate up to 7,000 l/min. Operating...
The IHPI-030V filter cartridge is used to remove the largest mechanical impurities from compressed air. Filtration capacity up to 5 um. Operating temperature from +1.5 to +65 °C.
The IHPN-030V filter cartridge is used to remove the largest mechanical impurities from compressed air. Filtration capacity up to 25 um. Operating temperature from +1.5 to +65 °C.
Filter with AAFMS2 molecular sieve capsule in 1" version designed as a fuse against moisture leakage into the air during shutdown of adsorption dryers according to ISO 8573-1...
MVAC medical vacuum filter with G1" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
SPFS sterile filter with G1 1/2" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G1 1/4" connection thread for high efficiency filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G1" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G1/2" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G2" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G2" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G3" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G3" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
SPFS sterile filter with G3/4" connection thread for highly efficient filtration of compressed air, process air and industrial gases. Filtration capacity less than 0.01 um...
MVAC medical vacuum filter with DN100 flange connection designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
MVAC medical vacuum filter with DN80 flange connection designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....
MVAC medical vacuum filter with G3" connection thread designed for effective removal of solid and liquid impurities and bacteria from the suction side of vacuum pumps....