Industrial compressed air filters ISO 8573
Get rid of mechanical impurities and oil from compressed air efficiently with our extensive filtration programme. Not only will you get better quality compressed air to suit more applications, but you will also extend the life of many compressor system components. If the above matters to you, please feel free to explore our filtration category properly. You will find Omega Air filters, B-Air filters or NGF and Mark filters. We also offer new filter, catalyst and adsorption inserts for all filters. More about the whole program and filtering principles in the sequel.
#ShowMore#
Why is it necessary to filter compressed air?
The compressed air produced by your compressor - whether piston or screw - is not of good quality without post-treatment and is not suitable for many applications. This is because the compressor inlet filter only captures part of the mechanical impurities. However, they are not the only problem that degrades the quality of the produced air.
What does the produced compressed air contain?
- mechanical impurities
- humidity
- oil vapours (if it is an oil compressor)
This harmful triple combination is causing great trouble for any equipment that is connected to the compressor. Pneumatic tools - over time, they lose power and increase consumption, corrode inside, destroy seals, clog holes, become stuck and negatively affect the quality of work. Its lifetime is shortened many times over. Imagine what untreated compressed air can do to the individual components of a large automated line full of valves, cylinders and variously controlled moving parts. Shutting down a line for servicing can cost a company hundreds of thousands.
Compressed air quality
Compressed air quality is described in standardsiSO 8573-1 with seven classes, from 0 to 6. This guideline is crucial for every operator, as it sets out the exact quality requirements for different applications. Each class has a prescribed maximum content of solids, water and oil. We go into detail about this issue in this article, which will give you advice on how to choose water filters to connect behind your compressor: How to filter compressed air
In addition to the filters themselves, you may also be interested in:
- filter inserts for activated carbon filters
- filter inserts for microfilters
- filter inserts for dust filters
- catalytic filter inserts
- adsorption filter inserts
- air filter cartridge contamination indicators
Filters according to the quality class of solid impurities:
- quality class 1
- quality class 2
- quality class 3
- quality class 4
- quality class 5
- quality class 6
- quality class 7
Industrial filters divided according to condensate discharge:
- Omega air filters; pressure 16 to 64 bar
- High pressure filters; 100 - 400 bar
- NGF air filtration; including clogging indication
- Stainless steel process filters; air and gas distribution
- Sterile stainless steel filters; SFS and SPF filtration
- Vacuum filters; filtration for vacuum
- PPA filter system; for painting equipment
- B-AIR filtration; for breathable air
- Filters in AFS design; silicone-free filtration
- Accessories for filters; inserts, indications,...
Bestsellers
Simple mechanical device for checking the condition of the filter cartridge. Contributes to reducing power consumption by alerting to high pressure gradients. If the filter...
AAFC cyclone separator in 1/2" design with a flow rate of 1,300 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFC cyclone separator in 3/8" design with a flow rate of 1,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
AAFM 1/2" pre-filter for removing fine impurities up to 0.1 um from compressed air according to ISO 8573-1 class 2. Body with easily removable container and designed for a flow...
Electronic timed condensate drain for compressed air systems up to 50 bar, operating on a time switching valve. External mounting on the filter body with 1/2" thread. Simple...
Float-operated condensate drain valve for compressed air systems up to 20 bar. Version AOK20B for external mounting on the filter body with 1/2" thread.
Replacement cyclone cartridge for liquid water filtration AAFC-78V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
The AFS filter insert is used to remove the largest mechanical impurities from compressed air up to 0.01 um according to ISO 8573-1 class 1. Easy replacement thanks to removable...
AFM prefilters according to ISO 8573.1. Filtration capacity 0,1 um, residual oil 0,1 mg/m3. AFM filters are used to remove coarse mechanical impurities from compressed air and...
Electronic timed condensate drain for compressed air systems up to 16 bar, operating on a time switching valve. External mounting on the filter body with 1/2" thread. Simple...
AAFS 1/2" microfilter to remove micro impurities up to 0.01 um from compressed air according to ISO 8573-1 class 1. Body with easily removable container and designed for a flow...
Kit for wall mounting and connecting filters. The set consists of two angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Connecting...
AAFA activated carbon filter in 1/4" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
Hankison 's NGF series NGF type PF basic ISO compressed air filtration. Filter size F03 with 3/8" female threads. The filter is equipped with a clogging indicator and an...
Hankison 's NGF series NGF type PF basic ISO compressed air filtration. Filter size F04 with 1/2" female thread connection. The filter is equipped with a clogging indicator and...
Hankison 's NGF series NGF type PF basic ISO compressed air filtration. Filter size F07 with 3/4" female thread connection. The filter is equipped with a clogging indicator and...
Hankison 's NGF series NGF type PF basic ISO compressed air filtration. Filter size F06 with 3/4" female thread connection. The filter is equipped with a clogging indicator and...
AAFA activated carbon filter in 1/2" version for absorption of residual oil, oil vapours and aerosols with < 0,005 mg/m3 from compressed air according to ISO 8573-1 class 1....
AAFP basic filter in 1/2" design for removal of basic mechanical impurities up to 3 um from compressed air according to ISO 8573-1 class 6. Body with easily removable container...
Float valve for condensate discharge from compressed air system working on float principle. Version AOK16B for internal mounting of filter vessels using 1/2" thread.
Kit for wall mounting and connecting filters. The set consists of two angles that are attached to the edges of the filter and allow subsequent mounting on the wall. Connecting...
Hankison filter cartridge for the PF series air filter type F02. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of...
Hankison filter cartridge for HF series air filter type F07. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F06 with 3/4" female thread connection. The filter is equipped with a clogging indicator and an...
Hankison brand filter cartridge for PF series air filter type F07. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of...
Replacement cyclone cartridge for liquid water filtration AAFC-198V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element by...
Dust filter AAFR in 1/2" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
Connection set for easy connection of two or more filters into one block in 1 1/2" threaded design. Universal design allowing the connection of filters from different...
Replacement cyclone cartridge for liquid water filtration AAFC-1500V. Recommended replacement 12 months or every 4,000 MH and upon indication of clogging of the filter element...
Replacement microfilter cartridge with filtration capacity of 0.01 µm for OMEGA AIR AAFS-25 and AAFS-30 microfilters. Recommended replacement 12 months or every 4,000 MH and...
Dust filter AAFR in 1/4" design to remove dust impurities up to 1 um from compressed air according to ISO 8573-1 class 3. Body with easily removable container and designed for a...
Replacement fine filter cartridge with 0.1 µm filtration capacity for OMEGA AIR AAFM-78 pre-filter. Recommended replacement 12 months or every 4,000 MH and when clogging of the...
Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F03 with 3/8" female threads. The filter is equipped with a clogging indicator and an automatic...
AAFC 2" cyclone separator with a flow rate of 25,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the rotation and...
Hankison filter cartridge for SF series air filter type F04. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
AAFC cyclone separator in 3" design with a flow rate of 36,000 l/min for partial removal of condensate from compressed air. Here the flow changes to rotational and due to the...
Hankison filter cartridge for HF series air filter type F03. The filter insert is suitable for easy replacement by means of a thread in the filter. The maximum pressure of the...
Replacement catalytic filters (hopcalite) for OMEGA AIR - AAFH2-198. Suitable for removing CO andCO2 to the level of breathable air from compressed air according to ISO 8573-1...
Prefilter for compressed air from Hankison NGF series of HF type according to ISO. Filter size F02 with 1/4" female thread connection. The filter is equipped with a clogging...
Hankison 's NGF series SF type basic ISO filter for compressed air. Filter size F02 with 1/4" female thread connection. The filter is equipped with a clogging indicator and an...